Abstract
Limited operating duration constrains solar-powered irrigation services for a local farmer group in Lebo Jaya Village, South Konawe Regency. This community service activity involved five participants around September 2026 and evaluated the compatibility of energy supply and pump demand through farmer feedback, facility documentation, and PVsyst assessment. The system comprises ten 600 Wp photovoltaic modules, totalling 6 kWp, tilted at 20° and facing north. The nominal pump rating is 5,000 W. The battery module is labelled lithium 48 V and 100 Ah, equivalent to 4.8 kWh of nominal energy per module. Farmers reported approximately 30 minutes of operation. The assessment indicates an energy supply issue involving battery storage. Under a constant 5 kW electrical input assumption, a 30-minute run requires 2.5 kWh; this analytical calculation does not establish usable battery capacity. Recommendations address initial charge, discharge limits, power capability, protection, and photovoltaic supply. The outcome is an identified operational constraint and directions for improvement. Post-intervention service gains require field verification.